R&S
FPL1000
CALCulate<n>:LIMit<li>:NAME <Name>
This command selects a limit line that already exists or defines a name for a new limit
line.
Suffix:
<n>
<li>
Parameters:
<Name>
Manual operation:
CALCulate<n>:LIMit<li>:UNIT <Unit>
This command defines the unit of a limit line.
Suffix:
<n>
<li>
Parameters:
<Unit>
Manual operation:
CALCulate<n>:LIMit<li>:UPPer[:DATA] <LimitLinePoints>
This command defines the vertical definition points of an upper limit line.
Suffix:
<n>
<li>
Manuel d'utilisation 1179.5860.09 - 12
Setting basic spectrum RF measurement parameters
Window
Limit line
String containing the limit line name.
*RST:
REM1 to REM8 for lines 1 to 8
See
"Name"
on page 440
irrelevant
Limit line
DBM | DBPW | WATT | DBUV | DBMV | VOLT | DBUA |
AMPere | DB | DBUV_M | DBUA_M | DBM_mhz | DBUV_mhz |
DBMV_mhz | DBUa_mhz | DBUV_m | DBUa_m | DBUV_mmhz |
DBUa_mmhz | DBPW_mhz | DBPT_mhz | DBPT | (unitless)
If you select a dB-based unit for the limit line, the command
automatically turns the limit line into a relative limit line.
*RST:
DBM
See
"Y-Axis"
on page 441
irrelevant
Limit line
Remote commands
914