R&S
FPL1000
[SENSe:]LIST:RANGe<ri>:FILTer:TYPE <FilterType>
This command selects the filter type for a spurious emission measurement range.
The EMI-specific filter types are available if the EMI (R&S FPL1-K54) measurement
option is installed, even if EMI measurement is not active. For details see
bandwidth and filter types"
Suffix:
<ri>
Parameters:
<FilterType>
Example:
Manual operation:
[SENSe:]LIST:RANGe<ri>:INPut:ATTenuation <Attenuation>
This command defines the input attenuation for a spurious emission measurement
range.
Suffix:
<ri>
Parameters:
<Attenuation>
Example:
Manual operation:
Manuel d'utilisation 1179.5860.09 - 12
Configuring and performing measurements
on page 259.
1..30
Selects the measurement range.
NORMal
Gaussian filters
CFILter
channel filters
RRC
RRC filters
CISPr | PULSe
CISPR (6 dB) - requires EMI (R&S FPL1-K54) option
Return value for query is always PULS.
MIL
MIL Std (6 dB) - requires EMI (R&S FPL1-K54) option
P5
5 Pole filters
*RST:
NORM
The available bandwidths of the filters are specified in the data
sheet.
LIST:RANG2:FILT:TYPE NORM
See
"Filter Type"
on page 211
1..n
Selects the measurement range.
Numeric value.
Refer to the data sheet for the attenuation range.
*RST:
10 dB
Default unit: dB
LIST:RANG2:INP:ATT 5
See
"RF Attenuation"
on page 212