Télécharger Imprimer la page

Rohde & Schwarz FPL1000 Manuel D'utilisation page 662

Masquer les pouces Voir aussi pour FPL1000:

Publicité

Les langues disponibles

Les langues disponibles

®
R&S
FPL1000
Suffix:
<sb>
Parameters:
<State>
Example:
Manual operation:
[SENSe:]ESPectrum<sb>:RANGe<ri>:BANDwidth:RESolution <RBW>
This command defines the resolution bandwidth for a SEM range.
In case of high speed measurements, the resolution bandwidth has to be identical for
all ranges.
Suffix:
<sb>
<ri>
Parameters:
<RBW>
Manual operation:
[SENSe:]ESPectrum<sb>:RANGe<ri>:BANDwidth:VIDeo <VBW>
This command defines the video bandwidth for a SEM range.
In case of high speed measurements, the video bandwidth has to be identical for all
ranges.
Suffix:
<sb>
<ri>
Parameters:
<VBW>
Manuel d'utilisation 1179.5860.09 - 12
Configuring and performing measurements
1 to 3
ON | OFF | 0 | 1
OFF | 0
Switches the function off
ON | 1
Switches the function on
ESP:HSP ON
See
"Fast SEM"
on page 181
1 to 3
1..n
Selects the measurement range.
Resolution bandwidth.
Refer to the data sheet for available resolution bandwidths.
*RST:
30.0 kHz
Default unit: Hz
See
"RBW"
on page 181
1 to 3
1..n
Selects the measurement range.
Video bandwidth.
Refer to the data sheet for available video bandwidths.
*RST:
10.0 MHz
Default unit: Hz
Remote commands
662
662

Publicité

loading