R&S
FPL1000
CONFigure:CMEasurement:RESult:P3DB[:STAT] <State>
Enables or disables the calculation of the 3 dB compression point.
To query the results of the 3 dB compression point measurement, use
CMEasurement:P3DB[:RESult]?
Parameters:
<State>
Example:
Manual operation:
CONFigure:CMEasurement:RESult:PNDB[:STAT] <State>
Enables or disables the calculation of the n dB compression point.
To define the compression value, use
on page 627.
To query the results of the n dB compression point measurement, use
CMEasurement:PNDB[:RESult]?
Parameters:
<State>
Example:
Manual operation:
CONFigure:CMEasurement[:STATe] <State>
Enables or disables the compression point measurement.
Manuel d'utilisation 1179.5860.09 - 12
Configuring and performing measurements
on page 629.
ON | OFF | 0 | 1
OFF | 0
Switches the function off
ON | 1
Switches the function on
*RST:
1
Enable calculation:
CONF:CME:REF:P3DB ON
Query results:
FETC:CME:P3DB?
See
"Compression Points"
CONFigure:CMEasurement:RESult:CVALue
on page 629.
ON | OFF | 0 | 1
OFF | 0
Switches the function off
ON | 1
Switches the function on
*RST:
0
Enable calculation:
CONF:CME:REF:PNDB ON
Define compression value:
CONF:CME:RES:CVAL 5
Query results:
FETC:CME:PNDB?
See
"Compression Points"
Remote commands