R&S
FPL1000
Return values:
<Power>
Example:
Usage:
CALCulate<n>:MARKer<m>:FUNCtion:BPOWer:SPAN <Span>
This command defines the bandwidth around the marker position.
Suffix:
<n>
<m>
Parameters:
<Span>
Example:
Manual operation:
CALCulate<n>:MARKer<m>:FUNCtion:BPOWer[:STATe] <State>
This command turns markers for band power measurements on and off.
Suffix:
<n>
<m>
Parameters:
<State>
Example:
Manuel d'utilisation 1179.5860.09 - 12
Setting basic spectrum RF measurement parameters
Signal power over the marker bandwidth.
Activate the band power marker:
CALC:MARK:FUNC:BPOW:STAT ON
Select the density mode for the result:
CALC:MARK:FUNC:BPOW:MODE DENS
Query the result:
CALC:MARK:FUNC:BPOW:RES?
Response:
20dBm/Hz
Query only
Window
Marker
Frequency. The maximum span depends on the marker position
and R&S FPL1000 model.
*RST:
5% of current span
Default unit: Hz
CALC:MARK:FUNC:BPOW:SPAN 2MHz
Measures the band power over 2 MHz around the marker.
See
"Span"
on page 385
Window
Marker
ON | OFF | 0 | 1
OFF | 0
Switches the function off
ON | 1
Switches the function on
CALC:MARK4:FUNC:BPOW:STAT ON
Activates or turns marker 4 into a band power marker.
Remote commands