Télécharger Imprimer la page

Rohde & Schwarz FPL1000 Manuel D'utilisation page 827

Masquer les pouces Voir aussi pour FPL1000:

Publicité

Les langues disponibles

Les langues disponibles

®
R&S
FPL1000
Parameters:
<History>
Example:
Manual operation:
CALCulate<n>:SGRam:LAYout <State>
CALCulate<n>:SPECtrogram:LAYout <State>
This command selects the state and size of spectrograms.
The command is available for result displays that support spectrograms.
Suffix:
<n>
Parameters:
<State>
Example:
Manual operation:
CALCulate<n>:SGRam[:STATe] <State>
CALCulate<n>:SPECtrogram[:STATe] <State>
This command turns the spectrogram on and off.
Parameters:
<State>
Example:
Manuel d'utilisation 1179.5860.09 - 12
Setting basic spectrum RF measurement parameters
The maximum number of frames depends on the number of
sweep points.
Range:
781 to 20000
Increment: 1
*RST:
3000
//Set the history depth to 1500
CALC:SGR:SPEC 1500
See
"History Depth"
on page 420
Window
ON
Spectrogram and trace diagram share a window.
OFF
Only the trace diagram is displayed, the spectrogram is not.
*RST:
OFF
CALC4:SPEC:LAY FULL
Shows the spectrogram in window 4. The corresponding trace
diagram is hidden.
See
"State"
on page 419
ON | OFF | 0 | 1
OFF | 0
Switches the function off
ON | 1
Switches the function on
CALC:SGR ON
Activates the Spectrogram result display.
Remote commands
827