R&S
FPL1000
Suffix:
<n>
Query parameters:
<Frames>
Return values:
<Seconds>
<Nanoseconds>
<Reserved>
<Reserved>
Example:
Usage:
Manual operation:
CALCulate<n>:SGRam:TSTamp[:STATe] <State>
CALCulate<n>:SPECtrogram:TSTamp[:STATe] <State>
This command activates and deactivates the time stamp.
If the time stamp is active, some commands do not address frames as numbers, but as
(relative) time values:
●
CALCulate<n>:DELTamarker<m>:SPECtrogram:FRAMe
●
CALCulate<n>:MARKer<m>:SPECtrogram:FRAMe
●
CALCulate<n>:SPECtrogram:FRAMe:SELect
Suffix:
<n>
Parameters:
<State>
Example:
Manuel d'utilisation 1179.5860.09 - 12
Setting basic spectrum RF measurement parameters
Window
CURRent
Returns the starting time of the current frame.
ALL
Returns the starting time for all frames. The results are sorted in
descending order, beginning with the current frame.
Number of seconds that have passed since 01.01.1970 till the
frame start
Number of nanoseconds that have passed in addition to the
<Seconds> since 01.01.1970 till the frame start.
The third value is reserved for future uses.
The fourth value is reserved for future uses.
CALC:SGR:TST:DATA? ALL
Returns the starting times of all frames sorted in a descending
order.
Query only
See
"Time Stamp"
on page 420
1..n
Window
ON | OFF | 0 | 1
OFF | 0
Switches the function off
ON | 1
Switches the function on
//Activates the time stamp
CALC:SGR:TST ON
Remote commands
on page 864
on page 859
on page 820
829
829