R&S
FPL1000
Suffix:
<n>
<m>
Example:
CALCulate<n>:MARKer<m>:FUNCtion:PNOise:RESult?
This command queries the result of a phase noise measurement.
If necessary, the command activates the measurement first.
Suffix:
<n>
<m>
Return values:
<PhaseNoise>
Example:
Usage:
CALCulate<n>:MARKer<m>:FUNCtion:PNOise[:STATe] <State>
This command turns the phase noise measurement at the marker position on and off.
Suffix:
<n>
<m>
Parameters:
<State>
Example:
10.8.8.11
Band power marker
The following commands control the marker for band power measurements.
Manuel d'utilisation 1179.5860.09 - 12
Setting basic spectrum RF measurement parameters
Window
irrelevant
CALC:MARK:FUNC:PNO:AOFF
Window
Marker
numeric value
The difference between the measured carrier power and the
noise power at the position of the specified (normal) marker.
CALC:MARK2:FUNC:PNO:RES?
Outputs the result of phase-noise measurement of the marker 2.
Query only
Window
Marker
ON | OFF | 0 | 1
OFF | 0
Switches the function off
ON | 1
Switches the function on
CALC:MARK2:FUNC:PNO ON
Switches on the phase-noise measurement for the marker 2.
Remote commands
883
883