R&S
FPL1000
10.8.7.1
Configuring standard traces
Useful commands for trace configuration described elsewhere
●
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:Y:SPACing
on page 776
●
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:Y[:SCALe]
on page 775
Remote commands exclusive to trace configuration
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:MODE
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:MODE:HCONtinuous
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>[:STATe]
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:SMOothing:APERture
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:SMOothing[:STATe]
[SENSe:]AVERage<n>:COUNt
[SENSe:]AVERage<n>[:STATe<t>]
[SENSe:]AVERage<n>:TYPE
[SENSe:][WINDow<n>:]DETector<t>[:FUNCtion]
[SENSe:][WINDow<n>:]DETector<t>[:FUNCtion]:AUTO
TRACe<n>:COPY
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:MODE <Mode>
This command selects the trace mode. If necessary, the selected trace is also activa-
ted.
In case of max hold, min hold or average trace mode, you can set the number of single
measurements with [SENSe:]SWEep:COUNt. Note that synchronization to the end of
the measurement is possible only in single sweep mode.
Suffix:
<n>
<w>
<t>
Parameters:
<Mode>
Manuel d'utilisation 1179.5860.09 - 12
Setting basic spectrum RF measurement parameters
................................................................................................ 815
................................................................................................ 815
.................................................................................................. 816
.................................................................................................................... 817
Window
subwindow
Not supported by all applications
Trace
WRITe
Overwrite mode: the trace is overwritten by each sweep. This is
the default setting.
AVERage
The average is formed over several sweeps. The "Sweep/Aver-
age Count" determines the number of averaging procedures.
MAXHold
The maximum value is determined over several sweeps and dis-
played. The R&S FPL1000 saves the sweep result in the trace
memory only if the new value is greater than the previous one.
Remote commands
.................................................. 812
............................................... 814
.................................................................... 816
......................................................... 817
........................... 813
.......................... 814
............................ 814
818
818