Example:
Manual operation:
[SENSe:]ESPectrum<sb>:RANGe<ri>:INPut:GAIN[:VALue] <Gain>
This command selects the gain for a SEM range.
In case of high speed measurements, the level of the preamplifier has to be identical
for all ranges.
Suffix:
<sb>
<ri>
[SENSe:]ESPectrum<sb>:RANGe<ri>:INPut:GAIN:STATe <State>
This command turns the preamplifier for a SEM range on and off.
In case of high speed measurements, the state of the preamplifier has to be identical
for all ranges.
Suffix:
<sb>
<ri>
Parameters:
<State>
Manual operation:
[SENSe:]ESPectrum<sb>:RANGe<ri>:INSert <Mode>
This command inserts a new SEM range and updates the range numbers accordingly.
Suffix:
<sb>
<ri>
Parameters:
<Mode>
Manuel d'utilisation 1179.5860.09 - 12
Configuring and performing measurements
ESP:RANG2:INP:ATT:AUTO OFF
Deactivates the RF attenuation auto mode for range 2.
See
"RF Att Mode"
on page 182
1 to 3
1..30
Selects the measurement range.
1 to 3
1..n
Selects the measurement range.
ON | OFF | 1 | 0
*RST:
0
See
"Preamp"
on page 183
1 to 3
1..n
Selects the SEM range.
AFTer | BEFore
AFTer
Inserts a range after the selected range.
BEFore
Inserts a range before the selected range.