R&S
FPL1000
Manual operation:
10.6.7.6
Configuring the power classes
The following commands define the power classes for SEM measurements.
CALCulate<n>:LIMit<li>:ESPectrum<sb>:LIMits
CALCulate<n>:LIMit<li>:ESPectrum<sb>:MODE
CALCulate<n>:LIMit<li>:ESPectrum<sb>:VALue
CALCulate<n>:LIMit<li>:ESPectrum<sb>:PCLass<pc>:COUNt
CALCulate<n>:LIMit<li>:ESPectrum<sb>:PCLass<pc>[:EXCLusive]
CALCulate<n>:LIMit<li>:ESPectrum<sb>:PCLass<pc>:LIMit[:STATe]
CALCulate<n>:LIMit<li>:ESPectrum<sb>:PCLass<pc>:MAXimum
CALCulate<n>:LIMit<li>:ESPectrum<sb>:PCLass<pc>:MINimum
CALCulate<n>:LIMit<li>:ESPectrum<sb>:LIMits <Max1>,<Max2>,<Max3>
This command sets or queries up to 4 power classes in one step. You can only define
values for the number of power classes defined by
ESPectrum<sb>:PCLass<pc>:COUNt
Suffix:
<n>
<li>
<sb>
Setting parameters:
<Max1>
<Max2>
Manuel d'utilisation 1179.5860.09 - 12
Configuring and performing measurements
CPOWer
Measures the channel power within the reference range (integral
bandwidth method).
*RST:
CPOWer
See
"Power Reference Type"
...................................................................... 671
.................................................................... 672
.................................................................... 672
on page 673.
irrelevant
irrelevant
1 to 3
Defines the value range for power class 1 as -200 to
<Max1>.
Only available for CALC:LIM:ESP:PCL:COUNT >=2
If only 2 power classes are defined, the value range for power
class 2 is defined as <Max1> to 200.
Range:
-199 to + 199
Default unit: DBM
Defines the value range for power class 2 as <Max1> to
<Max2>.
Only available for CALC:LIM:ESP:PCL:COUNT >=3
If only 3 power classes are defined, the value range for power
class 3 is defined as <Max2> to 200.
Range:
-199 to + 199, <Max2> must be higher than
<Max1>
Remote commands