Example:
Manual operation:
Configuring power sensor measurements
CALibration:PMETer<p>:ZERO:AUTO ONCE
CALCulate<n>:PMETer<p>:RELative[:MAGNitude]
CALCulate<n>:PMETer<p>:RELative[:MAGNitude]:AUTO ONCE
CALCulate<n>:PMETer<p>:RELative:STATe
FETCh:PMETer<p>?
READ:PMETer<p>?
[SENSe:]PMETer<p>:DCYCle[:STATe]
[SENSe:]PMETer<p>:DCYCle:VALue
[SENSe:]PMETer<p>:FREQuency
[SENSe:]PMETer<p>:FREQuency:LINK
[SENSe:]PMETer<p>:MTIMe
[SENSe:]PMETer<p>:MTIMe:AVERage:COUNt
[SENSe:]PMETer<p>:MTIMe:AVERage[:STATe]
[SENSe:]PMETer<p>:ROFFset[:STATe]
[SENSe:]PMETer<p>:SOFFset
[SENSe:]PMETer<p>[:STATe]
[SENSe:]PMETer<p>:UPDate[:STATe]
UNIT<n>:PMETer<p>:POWer
UNIT<n>:PMETer<p>:POWer:RATio
CALibration:PMETer<p>:ZERO:AUTO ONCE
This command zeroes the power sensor.
Note that you have to disconnect the signals from the power sensor input before you
start to zero the power sensor. Otherwise, results are invalid.
Suffix:
<p>
Example:
Usage:
Manual operation:
Manuel d'utilisation 1179.5860.09 - 12
Setting basic spectrum RF measurement parameters
SYST:COMM:RDEV:PMET2:DEF '','NRP-Z81','',
'123456'
Assigns the power sensor with the serial number '123456' to the
configuration "Power Sensor 2".
SYST:COMM:RDEV:PMET2:DEF?
Queries the sensor assigned to "Power Sensor 2".
Result:
'','NRP-Z81','USB','123456'
The NRP-Z81 power sensor with the serial number '123456' is
assigned to the "Power Sensor 2".
See
"Select"
on page 287
.......................................................................... 790
................................................................................................................ 791
................................................................................................................. 791
.......................................................................................... 791
..................................................................................... 791
........................................................................................... 792
.................................................................................. 792
................................................................................................... 793
........................................................................................ 794
................................................................................................ 794
........................................................................................................ 794
.......................................................................................... 795
.................................................................................................. 795
....................................................................................... 795
Power sensor index
CAL:PMET2:ZERO:AUTO ONCE;*WAI
Starts zeroing the power sensor 2 and delays the execution of
further commands until zeroing is concluded.
Event
See
"Zeroing Power Sensor"
......................................................................... 789
................................................................ 790
.......................................... 790
...................................................................... 793
........................................................................... 793
on page 287
Remote commands
795
795

Publicité

loading