R&S
FPL1000
[SENSe:]PMETer<p>:MTIMe <Duration>
This command selects the duration of power sensor measurements.
Suffix:
<p>
Parameters:
<Duration>
Example:
Manual operation:
[SENSe:]PMETer<p>:MTIMe:AVERage:COUNt <NumberReadings>
This command sets the number of power readings included in the averaging process of
power sensor measurements.
Extended averaging yields more stable results for power sensor measurements, espe-
cially for measurements on signals with a low power, because it minimizes the effects
of noise.
Suffix:
<p>
Parameters:
<NumberReadings> An average count of 0 or 1 performs one power reading.
Example:
Manual operation:
[SENSe:]PMETer<p>:MTIMe:AVERage[:STATe] <State>
This command turns averaging for power sensor measurements on and off.
Suffix:
<p>
Parameters:
<State>
Manuel d'utilisation 1179.5860.09 - 12
Setting basic spectrum RF measurement parameters
Power sensor index
SHORt | NORMal | LONG
*RST:
NORMal
PMET2:MTIM SHOR
Sets a short measurement duration for measurements of station-
ary high power signals for the selected power sensor.
See
"Meas Time/Average"
Power sensor index
Range:
0 to 256
Increment: binary steps (1, 2, 4, 8, ...)
PMET2:MTIM:AVER ON
Activates manual averaging.
PMET2:MTIM:AVER:COUN 8
Sets the number of readings to 8.
See
"Average Count (Number of Readings)"
Power sensor index
ON | OFF | 0 | 1
OFF | 0
Switches the function off
Remote commands
on page 288
on page 289
799