Manual operation:
[SENSe:]ESPectrum<sb>:RANGe<ri>:COUNt?
This command queries the number of ranges in the sweep list.
Suffix:
<sb>
<ri>
Return values:
<Ranges>
Usage:
[SENSe:]ESPectrum<sb>:RANGe<ri>:DELete
This command removes a range from the sweep list.
Note that
you cannot delete the reference range
a minimum of three ranges is mandatory.
Suffix:
<sb>
<ri>
Manual operation:
[SENSe:]ESPectrum<sb>:RANGe<ri>:FILTer:TYPE <FilterType>
This command selects the filter type for an SEM range.
In case of high speed measurements, the filter has to be identical for all ranges.
The EMI-specific filter types are available if the EMI (R&S FPL1-K54) measurement
option is installed, even if EMI measurement is not active. For details see
bandwidth and filter types"
Suffix:
<sb>
<ri>
Parameters:
<FilterType>
Manuel d'utilisation 1179.5860.09 - 12
Configuring and performing measurements
See
"VBW"
on page 182
1 to 3
irrelevant
Number of ranges in the sweep list.
Query only
1 to 3
Selects the measurement range.
See
"Delete Range"
on page 185
on page 259.
1 to 3
1...30
Selects the measurement range.
NORMal
Gaussian filters
CFILter
channel filters
RRC
RRC filters
Remote commands