INSTrument:DELete <ChannelName>
This command deletes a channel setup.
Setting parameters:
<ChannelName>
Usage:
Manual operation:
INSTrument:LIST?
This command queries all active channel setups. This is useful in order to obtain the
names of the existing channel setups, which are required in order to replace or delete
the channel setups.
Return values:
<ChannelType>,
<ChannelName>
Example:
Usage:
Manual operation:
Table 10-2: Available channel setup types and default channel setup names
Application
Spectrum
AM/FM/PM Modulation
Analysis
I/Q Analyzer
Noise Figure Measure-
ments
Vector Signal Analysis
(VSA)
Note: the default channel setup name is also listed in the table. If the specified name for a new channel
setup already exists, the default name, extended by a sequential number, is used for the new channel
setup.
Manuel d'utilisation 1179.5860.09 - 12
Selecting the operating mode and application
String containing the name of the channel setup you want to
delete.
A channel setup must exist in order to be able delete it.
Setting only
See
"Closing a channel setup"
For each channel setup, the command returns the channel setup
type and channel setup name (see tables below).
Tip: to change the channel setup name, use the
REName
command.
INST:LIST?
Result for 3 channel setups:
'ADEM','Analog Demod','IQ','IQ
Analyzer','IQ','IQ Analyzer2'
Query only
See
"Changing the Channel setup Name"
See
"Defining a channel setup"
See
"New Channel Setup"
<ChannelType> Parameter
SANALYZER
ADEM
IQ
NOISE
DDEM
Remote commands
on page 89
INSTrument:
on page 70
on page 88
on page 89
Default Channel setup Name*)
Spectrum
Analog Demod
IQ Analyzer
Noise
VSA