//Retrieve the measured frequencies (10 Hz - 10 MHz)
TRAC:DATA:X? TRACE1
//Retrieve the measured power levels;
TRAC:DATA? TRACE1
//--------------Normalizing the calibration trace results -----------
//Retrieve the normalized power levels (= power offsets from calibration results)
//Should be 0 for all sweep points directly after calibration
SENS:CORR:STAT ON
TRAC:DATA? TRACE1
//--------------Changing the display of the calibration results -----------
//Shift the reference line so the -5 dB level is displayed in the center
DISP:TRAC:Y:SCAL:RVAL -5DB
DISP:TRAC:Y:SCAL:RPOS 50PCT
10.8.5.4
Configuring the outputs
The following commands are required to provide output from the R&S FPL1000.
Output functions require the option R&S FPL1-B5 to be installed on the R&S FPL1000.
DIAGnostic:SERVice:NSOurce
OUTPut<up>:IF[:SOURce]
OUTPut<up>:IF:IFFRequency
OUTPut<up>:UPORt:STATe
OUTPut<up>:UPORt[:VALue]
OUTPut:UPORt:WTRigger:POLarity
SYSTem:SPEaker[:STATe]
SYSTem:SPEaker:MUTE
SYSTem:SPEaker:VOLume
DIAGnostic:SERVice:NSOurce <State>
This command turns the 28 V supply of the BNC connector labeled [noise source
control] on the R&S FPL1000 on and off.
Parameters:
<State>
Example:
Manual operation:
Manuel d'utilisation 1179.5860.09 - 12
Setting basic spectrum RF measurement parameters
................................................................................................ 804
....................................................................................................... 805
................................................................................................. 805
........................................................................................................... 805
.................................................................................................. 806
........................................................................................ 806
................................................................................................................... 807
......................................................................................................... 807
..................................................................................................... 807
ON | OFF | 0 | 1
OFF | 0
Switches the function off
ON | 1
Switches the function on
DIAG:SERV:NSO ON
See
"Noise Source Control"
Remote commands
on page 308