Parameters:
<LimitLinePoints>
Manual operation:
CALCulate<n>:LIMit<li>:CONTrol:DOMain <SpanSetting>
This command selects the domain of the limit line.
Suffix:
<n>
<li>
Parameters:
<SpanSetting>
Example:
Manual operation:
CALCulate<n>:LIMit<li>:CONTrol:MODE <Mode>
This command selects the horizontal limit line scaling.
Suffix:
<n>
<li>
Parameters:
<Mode>
Manuel d'utilisation 1179.5860.09 - 12
Setting basic spectrum RF measurement parameters
Variable number of x-axis values.
Note that the number of horizontal values has to be the same as
the number of vertical values set with
LIMit<li>:LOWer[:DATA]
UPPer[:DATA]. If not, the R&S FPL1000 either adds missing
values or ignores surplus values.
The unit is Hz or s.
*RST:
-
Default unit: HZ
See
"Data Points"
on page 441
irrelevant
Limit line
FREQuency | TIME
FREQuency
For limit lines that apply to a range of frequencies.
TIME
For limit lines that apply to a period of time.
*RST:
FREQuency
CALC:LIM:CONT:DOM FREQ
Select a limit line in the frequency domain.
See
"X-Axis"
on page 441
irrelevant
Limit line
ABSolute
Limit line is defined by absolute physical values (Hz or s).
RELative
Limit line is defined by relative values related to the center fre-
quency (frequency domain) or the left diagram border (time
domain).
*RST:
ABSolute
Remote commands
CALCulate<n>:
CALCulate<n>:LIMit<li>: