10.6.13
Measuring the AM modulation depth
All remote control commands specific to AM modulation depth measurements are
described here.
Configuring and performing the measurement
Example: measuring the AM modulation depth
10.6.13.1
Configuring and performing the measurement
The following commands control the measurement.
Useful commands for AM modulation depth described elsewhere
CALCulate<n>:DELTamarker<m>:X
CALCulate<n>:DELTamarker<m>:X:RELative?
CALCulate<n>:MARKer<m>:X
Remote commands exclusive to AM modulation depth measurements
CALCulate<n>:MARKer<m>:FUNCtion:MDEPth[:STATe]
CALCulate<n>:MARKer<m>:FUNCtion:MDEPth:SEARchsignal ONCE
CALCulate<n>:MARKer<m>:FUNCtion:MDEPth:RESult<t>?
CALCulate<n>:MARKer<m>:FUNCtion:MDEPth[:STATe] <State>
This command turns the AM Modulation Depth measurement on and off.
To work correctly, the measurement requires an AM modulated signal.
Suffix:
<n>
<m>
Parameters:
<State>
CALCulate<n>:MARKer<m>:FUNCtion:MDEPth:SEARchsignal ONCE
This command initiates a search for the signals required for the AM depth measure-
ment.
Note that the command does not perform a new measurement, but looks for the sig-
nals on the current trace.
Suffix:
<n>
<m>
Manuel d'utilisation 1179.5860.09 - 12
Configuring and performing measurements
on page 841
on page 844
Window
Marker
ON | OFF | 1 | 0
*RST:
0
Window
Marker
Remote commands
.......................................................... 721
......................................................... 722
on page 857
....................................................... 721
.................................. 721
.................................................. 722
727
727

Publicité

loading