R&S
FPL1000
Parameters:
<State>
Example:
Manual operation:
CALCulate<n>:MARKer<m>:PEXCursion <Excursion>
This command defines the peak excursion (for all markers in all windows).
The peak excursion sets the requirements for a peak to be detected during a peak
search.
The unit depends on the measurement.
Application/Result display
Spectrum
Suffix:
<n>
<m>
Parameters:
<Excursion>
Example:
Manual operation:
CALCulate<n>:MARKer<m>:X:SLIMits[:STATe] <State>
This command turns marker search limits on and off for all markers in all windows.
If you perform a measurement in the time domain, this command limits the range of the
trace to be analyzed.
Suffix:
<n>
<m>
Parameters:
<State>
Manuel d'utilisation 1179.5860.09 - 12
Setting basic spectrum RF measurement parameters
ON | OFF | 0 | 1
*RST:
1
CALC:MARK:LOEX ON
See
"Exclude LO"
on page 364
Unit
dB
irrelevant
irrelevant
The excursion is the distance to a trace maximum that must be
attained before a new maximum is recognized, or the distance to
a trace minimum that must be attained before a new minimum is
recognized
*RST:
6 dB in the Spectrum application and RF displays
Default unit: DB
CALC:MARK:PEXC 10dB
Defines peak excursion as 10 dB.
See
"Peak Excursion"
irrelevant
irrelevant
ON | OFF | 0 | 1
OFF | 0
Switches the function off
Remote commands
on page 365
853