INSTrument:CREate[:NEW] <ChannelType>, <ChannelName>
This command adds an additional measurement channel. You can configure up to 10
measurement channels at the same time (depending on available memory).
See also
●
INSTrument[:SELect]
●
INSTrument:DELete
Parameters:
<ChannelType>
<ChannelName>
Example:
Manual operation:
INSTrument:CREate:REPLace <ChannelName1>,<ChannelType>,<ChannelName2>
This command replaces a channel setup with another one.
Setting parameters:
<ChannelName1>
<ChannelType>
<ChannelName2>
Example:
Usage:
Manual operation:
Manuel d'utilisation 1179.5860.09 - 12
Selecting the operating mode and application
on page 613
on page 612
Channel type of the new channel.
For a list of available channel types see
on page 612.
String containing the name of the channel.
Note that you can not assign an existing channel name to a new
channel; this will cause an error.
INST:CRE SAN, 'Spectrum 2'
Adds an additional spectrum display named "Spectrum 2".
See
"New Channel Setup"
String containing the name of the channel setup you want to
replace.
Channel type of the new channel setup.
For a list of available channel setup types see
LIST?
on page 612.
String containing the name of the new channel setup.
Note: If the specified name for a new channel setup already
exists, the default name, extended by a sequential number, is
used for the new channel setup (see
on page 612).
Channel names can have a maximum of 31 characters, and
must be compatible with the Windows conventions for file
names. In particular, they must not contain special characters
such as ":", "*", "?".
INST:CRE:REPL 'IQAnalyzer2',IQ,'IQAnalyzer'