R&S
FPL1000
10.6.7.4
Configuring a sweep list
The following commands define a sweep list for SEM measurements.
The sweep list cannot be configured using remote commands during an on-going
sweep operation.
See also:
●
CALCulate<n>:LIMit<li>:ESPectrum<sb>:PCLass<pc>:LIMit[:STATe]
on page 674
[SENSe:]ESPectrum<sb>:HSPeed
[SENSe:]ESPectrum<sb>:RANGe<ri>:BANDwidth:RESolution
[SENSe:]ESPectrum<sb>:RANGe<ri>:BANDwidth:VIDeo
[SENSe:]ESPectrum<sb>:RANGe<ri>:COUNt?
[SENSe:]ESPectrum<sb>:RANGe<ri>:DELete
[SENSe:]ESPectrum<sb>:RANGe<ri>:FILTer:TYPE
[SENSe:]ESPectrum<sb>:RANGe<ri>[:FREQuency]:STARt
[SENSe:]ESPectrum<sb>:RANGe<ri>[:FREQuency]:STOP
[SENSe:]ESPectrum<sb>:RANGe<ri>:INPut:ATTenuation
[SENSe:]ESPectrum<sb>:RANGe<ri>:INPut:ATTenuation:AUTO
[SENSe:]ESPectrum<sb>:RANGe<ri>:INPut:GAIN[:VALue]
[SENSe:]ESPectrum<sb>:RANGe<ri>:INPut:GAIN:STATe
[SENSe:]ESPectrum<sb>:RANGe<ri>:INSert
[SENSe:]ESPectrum<sb>:RANGe<ri>:LIMit<li>:ABSolute:STARt
[SENSe:]ESPectrum<sb>:RANGe<ri>:LIMit<li>:ABSolute:STOP
[SENSe:]ESPectrum<sb>:RANGe<ri>:LIMit<li>:RELative:STARt
[SENSe:]ESPectrum<sb>:RANGe<ri>:LIMit<li>:RELative:STARt:ABS
[SENSe:]ESPectrum<sb>:RANGe<ri>:LIMit<li>:RELative:STARt:FUNCtion
[SENSe:]ESPectrum<sb>:RANGe<ri>:LIMit<li>:RELative:STOP
[SENSe:]ESPectrum<sb>:RANGe<ri>:LIMit<li>:RELative:STOP:ABS
[SENSe:]ESPectrum<sb>:RANGe<ri>:LIMit<li>:RELative:STOP:FUNCtion
[SENSe:]ESPectrum<sb>:RANGe<ri>:LIMit<li>:STATe
[SENSe:]ESPectrum<sb>:RANGe<ri>:POINts:MINimum[:VALue]
[SENSe:]ESPectrum<sb>:RANGe<ri>:MLCalc
[SENSe:]ESPectrum<sb>:RANGe<ri>:RLEVel
[SENSe:]ESPectrum<sb>:RANGe<ri>:SWEep:TIME
[SENSe:]ESPectrum<sb>:RANGe<ri>:SWEep:TIME:AUTO
[SENSe:]ESPectrum<sb>:RANGe<ri>:TRANsducer
[SENSe:]ESPectrum<sb>:SSETup
[SENSe:]ESPectrum<sb>:HSPeed <State>
This command turns high speed mode for SEM measurements on and off.
For more information including restrictions see
on page 174.
Manuel d'utilisation 1179.5860.09 - 12
Configuring and performing measurements
.......................................................................................... 655
....................................................... 656
...................................................................... 657
........................................................................ 657
............................................................... 657
................................................... 658
.................................................... 658
...................................................... 659
.................................................... 660
..................................................... 660
.......................................................................... 660
.......................................................... 665
........................................................................ 666
........................................................................ 667
.............................................................. 667
................................................... 668
............................................................... 668
.......................................................................................... 669
"Fast SEM measurements"
Remote commands
............................................... 656
........................................... 659
........................................... 661
............................................ 661
........................................... 662
................................... 662
........................... 663
............................................ 663
.................................... 664
............................ 665
.......................................... 666
661
661