11) Connect the IAC valve 2P connector and tighten the 6 x 25
mm flange bolt securely.
12) Install the harness band clip.
13) Install the throttle rod on the throttle body.
14) Connect the IAT sensor 2P connector and the TP sensor 3P
connector.
15) Insert the breather tube up to the marked point into the
silencer.
16) Install the fuel hose (P. 5-88).
17) Install the engine cover (P. 4-2).
5-98
[1]
HARNESS BAND
CLIP
[2]
THROTTLE ROD
[1]
TP SENSOR 3P
CONNECTOR
[4]
MARK
764
6 x 25
[2]
IAC VALVE 2P
CONNECTOR
[1]
THROTTLE
BODY
[2]
BREATHER TUBE
[3]
IAT SENSOR 2P
CONNECTOR