Exemple : Paramètres machine
; FRAME - Configurations
$MC_MM_SYSTEM_FRAME_MASK = 'H1'
$MC_CHSFRAME_RESET_MASK = 'H41'
$MC_CHSFRAME_POWERON_MASK = 'H41'
$MN_FRAME_GEOAX_CHANGE_MODE = 1
$MC_RESET_MODE_MASK = 'H4041'
;$MC_RESET_MODE_MASK = 'H41'
;$MC_GCODE_RESET_VALUES[7] = 2
$MC_GCODE_RESET_VALUES[7] = 1
$MN_MM_NUM_GLOBAL_USER_FRAMES = 0
$MN_MM_NUM_GLOBAL_BASE_FRAMES = 3
$MC_MM_NUM_USER_FRAMES = 10
$MC_MM_NUM_BASE_FRAMES = 3
$MN_NCBFRAME_RESET_MASK = 'HFF'
$MC_CHBFRAME_RESET_MASK = 'HFF'
$MN_MIRROR_REF_AX = 0
$MN_MIRROR_TOGGLE = 0
$MN_MM_FRAME_FINE_TRANS = 1
$MC_FRAME_ADD_COMPONENTS = TRUE
; l'axe oblique est le 1er transformateur
$MC_TRAFO_TYPE_1 = 1024
$MC_TRAFO_AXES_IN_1[0] = 4
$MC_TRAFO_AXES_IN_1[1] = 3
$MC_TRAFO_AXES_IN_1[2] = 2
$MC_TRAFO_AXES_IN_1[3] = 0
$MC_TRAFO_AXES_IN_1[4] = 0
$MC_TRAFO_GEOAX_ASSIGN_TAB_1[0] = 4
Fonctions de base
Description fonctionnelle, 01/2023, A5E48764112D AE
Axes, systèmes de coordonnées, frames
; SETFRAME
; Les frames sont actives après le reset.
; Les frames sont supprimées à la "mise
sous tension".
; Les frames sont converties après la com-
mutation GeoAx.
; La frame de base n'est pas désélection-
née après RESET.
; La frame de base est désélectionnée
après RESET.
; G54 est le réglage par défaut.
; G500 est le réglage par défaut.
; de 5 à 100
; de 0 à 8
; Aucune normalisation lors de la fonc-
tion miroir.
; Décalage fin
; G58, G59 est possible.
; Axe oblique
; Axe parallèle à z
4.5 Frames
371