3.1.3 L
IFTING INSTRUCTIONS
1
Fig. 3.7
Lifting eye
When lifting the compressor, the hoist has to be placed in such a way
that the compressor, which must be placed level, will be lifted
vertically.
Preferably use the lifting eye (1) after opening the small door (2).
Lifting acceleration and retardation must be kept within
safe limits (max. 4xg).
Helicopter lifting is not allowed.
3.2
1. Before initial start-up, prepare battery for operation if not already
2. With the compressor standing level, check the level of the engine
3. Check the level of the compressor oil. The pointer of oil level
2
4. Check that the fuel tank contains sufficient fuel. Top up, if
5. Drain any water and sediment from the fuel filter until clean fuel
6. Press vacuator valve (VV- Fig. 2.3) of the air filter to remove
7. Check the air filter service indicator (VI- Fig. 2.3). If the yellow
8. Open an air outlet valve to allow air flow to the atmosphere.
B
EFORE STARTING
If the compressor is to be used for sand-blasting or will
be connected to a common compressed air system, fit an
appropriate check valve between compressor outlet and
the connected sand-blasting or compressed-air system.
See Atlas Copco option ÓNon-Return ValveÓ
Observe the right mounting position/direction !
done. See section 4.7.
oil. Add oil, if necessary, to the upper mark on the dipstick.
Consult the Engine Operation Manual for the type and viscosity
grade of the engine oil.
gauge (OLG- Fig. 2.3) should register in the green range. Add oil
if necessary. See section 4.3 for the oil to be used.
Before removing oil filler plug (FP - Fig. 2.3), ensure
that the pressure is released by opening an air outlet
valve.
necessary. Consult the Engine Operation Manual for the type of
fuel.
flows from the drain cock.
dust.
piston reaches the red marked service range, replace the filter
element. Reset the indicator by pushing the reset button.