MANUAL INJECTION PUMP
(E115AMH, E115AWH)
4034
4036
Inspecting steps
NOTE:
Do not overpressurize the manual injection
pump. Excessive pressure may cause air to
leak out.
(1) Install the Mity vac onto the manual
injection pump as shown.
Mity vac
YB-35956 / 90890-06756
(2) Block outlet valves and apply the spec-
ified pressure with the Mity vac.
Pump pressure
50 kPa (0.5 kg/cm
(3) Remove your fingers to open the out-
let valves.