NOTE: This SP is activated only when SP 5816-001 is set to "2".
Function Flag
Enables or disables the remote service function.
003
[0 to 1 / 0 / 1 /step]
0: Disabled
1: Enabled
SSL Disable
Controls if RCG (Remote Communication Gate) confirmation is done by SSL during an
RCG send for the @Remote over a network interface.
007
[0 or 1 / 0 / 1 /step]
0: Yes. SSL not used.
1: No. SSL used.
RCG Connect Timeout
Sets the length of time (seconds) for the time-out when the RCG (Remote Communication
008
Gate) connects during a call via the @Remote network.
[1 to 90 / 30 / 1 second /step]
RCG Write Timeout
Sets the length of time (seconds) for the time-out when sent data is written to the RCG during
009
a call over the @Remote network.
[1 to 100 / 60 / 1 second /step]
RCG Read Timeout
Sets the length of time (seconds) for the timeout when sent data is written from the RCG
010
during a call over the @Remote network.
[1 to 100 / 60 / 1 second /step]
Port 80 Enable
Controls if permission is given to get access to the SOAP method over Port 80 on the
@Remote network.
011
[0 or 1 / 0 / – ]
0: No. Access denied
1: Yes. Access granted.
-
System Service Mode
8