Ricoh MPC 2800 AT-C2 Mode D'emploi page 678

Table des Matières

Publicité

8. Appendix: SP Mode Tables
2: Medium (3K jams)
3: High (6K jams)
[Error Alarm]
Sets the error alarm level.
The error alarm counter counts "1" when any SC is detected. However, the error alarm
5505
counter decreases by "1" when an SC is not detected during a set number of copied sheets
(for example, default 1500 sheets).
The error alarm occurs when the SC error alarm counter reaches "5".
001 -
5507
[Supply Alarm]
001 Paper Supply Alarm
002 Staple Supply Alarm
003 Toner Supply Alarm
8
080 Toner Call Timing
128 Interval :Others
132 Interval :A3
133 Interval :A4
134 Interval :A5
141 Interval :B4
142 Interval :B5
160 Interval :DLT
164 Interval :LG
166 Interval :LT
310
[0 to 255 / C2a; 35, C2b; 45 / 100 copies /
*CTL
step]
*CTL
-
0: Off, 1: On, DFU
0: Off, 1: On
0: Off, 1: On, DFU
Changes the timing of the "Toner Supply Call" via the
@Remote, when the following conditions occur.
0: At replacement (default)
1: At near end
[250 to 10000 / 1000 / 1 /step] DFU