8. Appendix: SP Mode Tables
079 Fusing Exit Motor: 1200
Drum Adjust
100
Enables or disables the drum amplitude adjustment.
101 154mm/s:M
102 154mm/s:C
103 154mm /s:Y
104 115mm/s:M
105 115mm /s:C
106 115mm /s:Y
107 77mm/s:M
108 77mm /s:C
109 77mm /s:Y
1901
[Recovery Temp. Ope. Time]
8
004 -
1902
[Amplitude Control]
001 Execute
002 Result
003 Auto Execution
158
*ENG
[–4 to 4 / -0.2 / 0.01 %/step]
[0 or 1 / 1 / 1]
*ENG
0: Off, 1: On
*ENG
*ENG
[–7 to 7 / 0/ 1 step/step]
*ENG
*ENG
*ENG
[–9 to 9 / 0 / 1 step/step]
*ENG
*ENG
*ENG
[–14 to 14 / 0 / 1 step/step]
*ENG
*ENG
[0 to 60 / 10 / 1 sec/step] Not used
-
Execute drum phase adjustment.
[0 to 3 / 0 / 1]
Displays the result of drum phase adjustment.
*ENG
0: Successfully done
2: Sampling failure
3: Insufficient detection number
[0 or 1 / 1 / -]
Turns the automatic drum phase adjustment on or
*ENG
off.
0: Off, 1: On