8. Appendix: SP Mode Tables
[ID Sensor Detection Value: Vofset]
3311
Displays the ID sensor (regular) offset voltage for Vsg adjustments.
001 Voffset reg: Bk
002 Voffset reg: M
003 Voffset reg: C
004 Voffset reg: Y
005-007 Displays the ID sensor (diffusion) offset voltage for Vsg adjustments.
005 Voffset dif: M
006 Voffset dif: C
007 Voffset dif: Y
008-010 Displays the ID sensor offset voltage for Vsg adjustments.
008 Voffset TM (Front)
009 Voffset TM (Center)
010 Voffset TM (Rear)
8
3321
[Vsg Adjustment: Execution]
010 P/TM Sensor All
[Vsg Adjustment Result: Vsg]
3322
Displays the result value of the Vsg adjustment for each sensor.
001 Vsg reg: Bk
002 Vsg reg: M
003 Vsg reg: C
004 Vsg reg: Y
005 Vsg dif: M
006 Vsg dif: C
254
*ENG
[0 to 5 / 0 / 0.01 V/step]
*ENG
*ENG
[0 to 5.5 / 0 / 0.01 V/step]
*ENG
*ENG
*ENG
[0 to 5.5 / 0 / 0.01 V/step]
*ENG
*ENG
*ENG
[0 to 5.5 / 0 / 0.01 V/step]
*ENG
Execute the ID sensor initialization setting for
-
all sensors
*ENG
*ENG
*ENG
[0 to 5.5 / 0 / 0.01 V/step]
*ENG
*ENG
*ENG