Ricoh MPC 2800 AT-C2 Mode D'emploi page 445

Table des Matières

Publicité

No.
Type
Incorrect modem setting
Dial up fails due to the incorrect modem setting.
-004
-
Same as -001
Check and set the correct AT command (SP5819-160).
Communication line error
The supplied voltage is not sufficient due to the defective communication line or
defective connection.
-005
-
Same as -001
Consult with the user's local telephone company.
No.
Type
Incorrect dial up connection
-001: Program parameter error
-002: Program execution error
CTL
651
An unexpected error occurs when the modem (Embedded RCG-M) tries to call the
C
center with a dial up connection.
• Caused by a software bug
No action required because this SC does not interfere with operation of the machine.
No.
Type
EEPROM error
Retry of EEPROM communication fails three times after the machine has detected
the EEPROM error.
669
D
• Caused by noise
Turn the main power switch off and on.
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC Tables
3
77

Publicité