Ricoh MPC 2800 AT-C2 Mode D'emploi page 534

Table des Matières

Publicité

8. Appendix: SP Mode Tables
004
Y
[Color Registration Correction] FA
These values are the parameters for the automatic line position adjustment and are adjusted
2101
at the factory. However, you must input a value for SP2101-001 after replacing the laser
optics housing unit. For details, see "Laser Optics Housing Unit" in the "Replacement and
Adjustment" section. The value should be provided with the new laser optics housing unit.
001 Main Dot: Bk
002 Main Dot: M
003 Main Dot: C
004 Main Dot: Y
005 Sub Line: Bk
006 Sub Line: M
007 Sub Line: C
008 Sub Line: Y
8
2102
[Magnification Adjustment] DFU
001 Main Mag.: High Speed: Bk
002 Main Mag.: Medium Speed: Bk
003 Main Mag.: Low Speed: Bk
004 Main Mag.: High Speed: M
005 Main Mag.: Medium Speed: M
006 Main Mag.: Low Speed: M
007 Main Mag.: High Speed: C
008 Main Mag.: Medium Speed: C
009 Main Mag.: Low Speed: C
010 Main Mag.: High Speed: Y
011 Main Mag.: Medium Speed: Y
166
3: Adjustment incompleted
*ENG
*ENG
*ENG
[–512 to 511 / 0 / 1 dot/step]
*ENG
*ENG
*ENG
*ENG
[–16384 to 16383 / 0 / 1 line/step]
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
*ENG
These are results of the main scan
*ENG
length adjustment.
[0 to 560 / 280 / 1 /step]
*ENG
*ENG
*ENG
*ENG
*ENG

Publicité

Chapitres

Table des Matières
loading

Table des Matières