001 Threshold: t2
002 Threshold: t1
[Initial Process Control Setting]
Adjusts the threshold for the process control at power on.
3522
When the current condition has changed by more than the values of these SPs when
compared with the conditions at the previous operation, the process control at power on is
executed.
002 Non-use Time Setting
003 Temperature Range
004 Relative Humidity Range
005 Absolute Humidity Range
[Rapi_timer]
100
[Time Setting]
Adjusts the time-out time for the Rapi timer.
[Non-use Time Process Control Setting]
Adjusts the threshold for the process control at stand-by.
3531
When the current condition has changed by more than the values of these SPs when
compared with the conditions at the previous operation, the process control at stand-by is
executed.
001 Non-use Time Setting
002 Temperature Range
003 Relative Humidity Range
004 Absolute Humidity Range
005 Maximum Execution Number
3611
[Development Gamma: Display/Set]
*ENG
[20 or 30 / 25 / 1 deg/step]
*ENG
[0 or 15 / 15 / 1 deg/step]
*ENG
[0 to 1440 / 360 / 1 minute/step]
*ENG
[0 to 99 / 10 / 1°C/step]
*ENG
[0 to 99 / 50 / 1 %RH/step]
*ENG
[0 to 99 / 6 / 1 g/m
*ENG
[0 to 255 / 30 / 1 sec/step]
*ENG
[0 to 1440 / 360 / 1 minute/step]
*ENG
[0 to 99 / 10 / 1°C/step]
*ENG
[0 to 99 / 50 / 1 %RH/step]
*ENG
[0 to 99 / 6 / 1 g/m
Adjusts the maximum execution time for the
process control at stand-by.
*ENG
[0 to 99 / 10 / 1 time/step]
System Service Mode
3
/step]
3
/step]
8
265