Ricoh MPC 2800 AT-C2 Mode D'emploi page 531

Table des Matières

Publicité

004 Environmental Target: Y
[Charge AC Current: MH] Charge Roller AC Current Adjustment for MH
(Color)
2010
Displays/sets the AC current target of the charge roller for MH environment (Middle
temperature and High humidity). DFU
001 Environmental Target: Bk
002 Environmental Target: M
003 Environmental Target: C
004 Environmental Target: Y
[Charge AC Current: HH] Charge Roller AC Current Adjustment for HH
(Color)
2011
Displays/sets the AC current target of the charge roller for HH environment (High
temperature and High humidity). DFU
001 Environmental Target: Bk
002 Environmental Target: M
003 Environmental Target: C
004 Environmental Target: Y
2012
[Charge Output Control]
001 AC Voltage
2013
[Environmental Correction: PCU]
001 Current Environmental: Display *ENG
*ENG
*ENG
*ENG
[0 to 3000 / 1180 / 10 ųA/step]
*ENG
*ENG
*ENG
*ENG
[0 to 3000 / 1180 / 10 ųA/step]
*ENG
*ENG
Selects the AC voltage control type.
[0 or 1 / 0 / 1 /step]
*ENG
0: Process control
1: Manual control (AC voltages are decided
with SP2006.)
Displays the environmental condition, which is
measured in absolute humidity.
[1 to 5 / – / 1 /step]
System Service Mode
8
163

Publicité

Chapitres

Table des Matières
loading

Table des Matières