3. Appendix: Service Call Conditions
No.
Type
CTL
819
C
[0x5032]
[0x5245]
3
[0x5355]
[554C]
No.
Type
CTL
820
D
[0612]
No.
Type
CTL
833
C
[0F30]
[0F31]
[0F41]
[50B1]
92
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Fatal kernel error
Due to a control error, a RAM overflow occurred during system processing. One
of the following messages was displayed on the operation panel.
HAIC-P2 error
vm_pageout: VM is full
L2 status time out
USB error
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Self-diagnostics error: CPU
[XXXX]: Detailed error code
Cut-in in ASIC occurs.
• Defective ASIC
• Defective devices in which ASIC detects cut-in.
Replace the controller board.
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Self-diagnostic error 8: Engine I/F ASIC
• ASIC (Mandolin) for system control could not be detected. After the PCI
configuration, the device ID for the ASIC could not be checked.
Replace the BICU.
• ASIC (Mandolin) for system control could not be detected. After the PCI
configuration, the device ID for the ASIC could not be checked.
Replace the BICU
Could not initialize or read the bus connection.
• Check for loose connections at the mother board.
• System program defective
• Controller board defective
• Optional board defective
Replace controller firmware