8. Appendix: SP Mode Tables
1103
[Fusing Idling] Fusing Idling Adjustment
Idling Start Temp.
011
Specifies the temperature for the fusing idling start.
Forced Idling Stop
012
Enables or disables the fusing idling stop. If "1: ON" is selected and the temperature of the
heating roller reaches the temeparture specified by SP1103-013, the machine stops the
fusing idling.
Forced Idling Stop Temp.
013
Specifies the temperature for the fusing idling stop.
014 Minimum Idling Time
Extra Idling Time (L)
016
Specifies how long the extra idling operation is executed for each environment. Each
environment is determined with SP1112-001 and 002.
017 Extra Idling Time (H)
018 Extra Idling Time (M)
8
Pressure TempThreshold
019
Specifies the threshold temperature for the extra fusing idling.
020 Control Switch Temp
1104
[Idling Before Job]
Environment Threshold
Selects the environment threshold for the paper feed waiting.
001
0: LL condition
1: LL/MM conditions
2: All conditions
Pressure Temp Threshold
002
Specifies the threshold temperature for the paper feed waiting.
142
*ENG
[0 to 75 / 75 / 1 deg/step]
[0 to 1 / 0 / 1 /step]
*ENG
0: OFF, 1: ON
*ENG
[100 to 180 / 100 / 1 deg/step]
*ENG
[0 to 10 / 0 / 1 sec/step]
*ENG
[0 to 60 / 0 / 1 sec/step]
*ENG
[0 to 60 / 0 / 1 sec/step]
*ENG
*ENG
[0 to 160 / 100 / 1 deg/step]
*ENG
[0 to 25 / 25 / 1 deg/step]
*ENG
[0 to 2 / 2 / 1 /step]
*ENG
[0 to 160 / 150 / 1 /step]