Programmation du FM 353
Tableau 6-5
DB utilisateur pour le FM 353 (suite)
Adresse
Adresse
Décla-
absolue
relative
ration
253.2
+3.2
253.3
+3.3
253.4
+3.4
253.5
+3.5
253.6
+3.6
253.7
+3.7
254.0
+4.0
255.0
+5.0
256.0
+6.0
257.0
+7.0
258.0
+8.0
262.0
+12.0
266.0
+16.0
267.0
+17.0
268.0
+18.0
269.0
+19.0
=20.0
Données d'application :
270.0
stat
270.0
+0.0
274.0
+4.0
278.0
+8.0
282.0
+12.0
=16.0
Valeur réelle au changement bloc :
286.0
286.0
stat
Données de maintenance :
290.0
stat
290.0
+0.0
294.0
+4.0
298.0
+8.0
302.0
+12.0
306.0
+16.0
6-36
Variable
Type de donnée
M_2_EN
BOOL
M_3_EN
BOOL
TO_EN
BOOL
BIT3_5
BOOL
BIT3_6
BOOL
BIT3_7
BOOL
G_1_VAL
BYTE
G_2_VAL
BYTE
G_3_VAL
BYTE
BYTE7
BYTE
X_T_VAL
DINT
V_VAL
DINT
M_1_VAL
BYTE
M_2_VAL
BYTE
M_3_VAL
BYTE
TO_VAL
BYTE
END_STRUCT
FC RD_COM, contrat n 105
APP_DAT
STRUCT
APP1
DINT
APP2
DINT
APP3
DINT
APP4
DINT
END_STRUCT
FC RD_COM, contrat n 107
BLCK_EXT
DWORD
FC RD_COM, contrat n 108
SERV_DAT
STRUCT
OUT_VAL
DINT
ENC_VAL
DINT
PULS_ERR
DINT
KV_FA
DINT
FOLL_ERR
DINT
Valeur
Commentaire
par défaut
FALSE
groupe fonctions M 2
FALSE
groupe fonctions M 3
FALSE
correction d'outil
FALSE
réservé
FALSE
réservé
FALSE
réservé
B#16#0
n fonction G groupe 1
B#16#0
n fonction G groupe 2
B#16#0
n fonction G groupe 3
B#16#0
réservé
L#0
valeur
L#0
valeur
B#16#0
n fonction M groupe 1
B#16#0
n fonction M groupe 2
B#16#0
n fonction M groupe 3
B#16#0
n corr. outil
données d'applicat.
L#0
données applic. 1
L#0
données applic. 2
L#0
données applic. 3
L#0
données applic. 4
DW#16#0
valeur réelle changement de bloc
données de maintenance
L#0
valeur de fréquence de sortie
L#0
compteur d'impulsions
L#0
réservé
L#0
réservé
L#0
écart position consigne/position réelle
Module de positionnement FM 353 pour moteur pas à pas