Specification of high-performance vector convertor
Parameter address
1018
1019
101A
101B
101C
101D
101E
101F
1020
Note:
Communication setting value is percentage of relative value, namely 10000 corresponds to 100.00%,
-10000 corresponds to -100.00%. For frequency dimension, this percent is the percentage of
relatively largest frequency (P0-10). For the data of torque dimension, this percent is P2-10, A2-48,
A3-48, A4-48 (upper limit setting of torque respectively corresponds to first and second motor).
Input command order to frequency convertor: (only write)
Command word address
2000
Read status of frequency convertor: (only read)
Status word address
3000
Cryptographic check of parameter locking: (if returning to be 8888H, pass cryptographic check)
Password address
1F00
Parameter description
AI3 voltage before calibration
Linear speed
Current electrifying time
Current running time
PULSE frequency, unit 1Hz
Communication setting value
Actual feedback speed
Principal frequency X display
Auxiliary frequency Y display
Command function
0001: foreward operation
0002: reverse operation
0003: foreward inching
0004: reverse inching
0005: free halt
0006: deceleration halt
0007: fault reset
Status word function
0001: foreward operation
0002: reverse operation
0003: halt
Contents of inputting password
*****
- 174 -
Appendix