Parameter description
P7-10
P7-11
Load speed display decimal digits
P7-12
Setting range
Load speed setting for the decimal display. The following example illustrates the calculation of load speed:
If the load speed display coefficient 2.000 P7-06, P7-12 load speed to 2 decimal places (two decimal places), when the
inverter operating frequency 40.00Hz, the load speed: 40.00 * 2.000 = 80.00 (2 decimal places display)
If the drive is shut down, the load speed display setting frequency corresponding to the speed, that is, "to set the load speed."
To set the frequency 50.00Hz, for example, the stop state load speed: 50.00 * 2.000 = 100.00 (two decimal display)
P7-13
Cumulative power-time display from the factory started the drive.
This time reaches the set power-up time (P8-17), the inverter multi-function digital output (24) outputs ON signal.
P7-14
So far show the total power consumption of the drive.
P8 Group--Auxiliary function
P8-00
P8-01
P8-02
When you define the drive jog a given frequency and the deceleration time.
Jog running, start fixed direct start-up mode (P6-00 = 0), stop mode is fixed to decelerate stop (P6-10 = 0).
P8-03
P8-04
Product No.
Setting range
Software version number
Setting range
0
1
2
3
Cumulative power-up time
Setting range
The total power consumption
Setting range
Jog frequency
Setting range
Jog acceleration time
Setting range
Jog Deceleration time
Setting range
Acceleration time 2
Setting range
Deceleration time 2
Setting range
Specification of high-performance vector convertor
Factory default
Inverter product number
Factory default
Control panel software version number.
Factory default
Factory default
Factory default
Factory default
0.00Hz ~ maximum frequency
Factory default
Factory default
Factory default
Factory default
- 106 -
0
0 decimal places
1 decimal places
2 decimal places
3 decimal places
0h
0h~65535h
-
0 to 65535 KWh
2.00Hz
20.0s
0.00s~6500.0s
20.0s
0.00s~6500.0s
20.0s
0. 0s~6500.0s
20.0s
0. 0s~6500.0s