Specification of high-performance vector convertor
Target volume
PA-00
PA-01
This parameter is used to select target process PID given channel.
Set a target amount of process PID is a relative value, setting range 0.0% to 100.0%. The same amount is relatively PID
feedback amount, PID is the role of these two relatively the same amount.
PA-02
This parameter is used to select the process PID feedback signal path.
Process PID feedback amount for the relative value is set in the range of 0.0% to 100.0%.
1
1
Ti
S
Td*s+1
1
6-25 Principle block diagram of process PID
Figure
PID given source
Setting range
PID values given
Setting range
PID feedback source
Setting range
Feedback quantity
Factory default
0
1
2
3
4
5
6
Factory default
Factory default
0
1
2
3
4
5
6
7
8
- 124 -
Parameter description
PID Output control
P
0
PA-01 Set up
AI1
AI2
AI3
Pulse (DI5)
Communication
Multi-step instructions
50.0%
0.0%~100.0%
0
AI1
AI2
AI3
AI1-AI2
Pulse (DI5)
Communication
AI1+AI2
MAX (|AI1|,|AI2|)
MIN (|AI1|,|AI2|)