Télécharger Imprimer la page

MSW Motor Technics MSW-FI-7500 Manuel D'utilisation page 201

Publicité

Specification of high-performance vector convertor
Code
PA-19
PID parameter switching deviation 1
PA-20
PID parameter switching deviation 2
Initial PID
PA-21
PA-22
Hold time of initial PID
PA-23
Forward max. of two output bias 0.00%~100.00%
Reverse max. of two output bias 0.00%~100.00%
PA-24
PID integral property
PA-25
PID feedback loss detection
PA-26
value
PID feedback loss detection time 0.0s~20.0s
PA-27
PID stoppage operation
PA-28
Setting way of swing frequency 0: Relative to central frequency
Pb-00
Swing frequency range
Pb-01
Kick frequency range
Pb-02
Kick frequency cyle
Pb-03
Triangular wave rising time
Pb-04
Set length
Pb-05
Actual length
Pb-06
Number of pulses per meter
Pb-07
Set count value
Pb-08
Designated count value
Pb-09
Multi-stage command and simple PLC in PC group
Multi-stage command 0
PC-00
PC-01
Multi-stage command 1
PC-02
Multi-stage command 2
PC-03
Multi-stage command 3
PC-04
Multi-stage command 4
PC-05
Multi-stage command 5
PC-06
Multi-stage command 6
PC-07
Multi-stage command 7
Multi-stage command 8
PC-08
Name
Swing frequency, length and count of Pb group
Setting range
0.0%~PA-20
PA-19~100.0%
0.0%~100.0%
0.00~650.00s
Bit: Integral separation
0: Invalid; 1: Valid
Ten bit: Integral to whether to stop the
output limit
0: Continued integration
1: Stop Points
0.0%: do not judge feedback loss
0.1%~100.0%
0: Stop operation; 1: Shutdown operation
1: relative to the maximum frequency
0.0%~100.0%
0.0%~50.0%
0.1s~3000.0s
0.1%~100.0%
0m~65535m
0m~65535m
0.1~6553.5
1~65535
1~65535
-100.0%~100.0%
-100.0%~100.0%
-100.0%~100.0%
-100.0%~100.0%
-100.0%~100.0%
-100.0%~100.0%
-100.0%~100.0%
-100.0%~100.0%
-100.0%~100.0%
- 56 -
Functional parameter table
Default
Change
20.0%
80.0%
0.0%
0.00s
1.00%
1.00%
00
0.0%
0.0s
0
0
0.0%
0.0%
10.0s
50.0%
1000m
0m
100.0
1000
1000
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%

Publicité

loading