Specification of high-performance vector convertor
Input of inflection point 2 of AI curve 5
A6-12
Setting range
Setting for input of inflection point
A6-13
2 of AI curve 5
Setting range
Max. input of AI curve 5
A6-14
Setting range
A6-15
Setting range
Curve function curve 4 and curve 5 1 to 3 is similar to the curve, but the curve 1 to curve 3 a straight
line and the curve 4 and curve 5 for the 4-point curve, you can achieve a more flexible
correspondence. Figure 6-32 is a schematic curve curve 4 to 5.
AI maximum input correspondence
AI curve inflection point 1
corresponds to the setting
AI curve inflection point 2
AI minimum input correspondence
Curve 4 and 5 to set the curve should note that the minimum input voltage curve, the inflection point
voltage 1, 2 inflection point voltage, maximum voltage must be successively increased.
AI curve selection P33 is used to determine the analog input AI1 ~ AI3 how to choose five curves.
AI1 sets jump point
A6-24
Setting range
AI1 sets jump range
A6-25
Setting range
AI2 sets jump point
A6-26
Setting range
AI2 sets jump range
A6-27
Setting range
Setting for max. input of AI curve 5
Analog input
corresponding to
100 %
the set amount
0V( 0mA)
AI curve
inflection point 1
Corresponding setting
-100 %
Figure 6-32 Curves 4 and 5wiring diagram
Factory default
A6-10~A6-14
Factory default
-100.0%~100.0%
Factory default
A6-14~10.00V
Factory default
-100.0%~100.0%
AI curve
inflection point
2
10V(20mA)
Factory default
-100.0%~100.0%
Factory default
0.0%~100.0%
Factory default
-100.0%~100.0%
Factory default
0.0%~100.0%
- 146 -
Parameter description
6.00V
60.0%
10.00V
100.0%
AI input voltage
0.0%

Publicité