Télécharger Imprimer la page

MSW Motor Technics MSW-FI-7500 Manuel D'utilisation page 209

Publicité

Specification of high-performance vector convertor
SVC optimization model
A5-07
A5-08
Dead-time adjustment
Code
A6-00
Min. input of AI curve 4
A6-01
Setting for min. input of AI curve 4
A6-02
Input of inflection point 1 of AI curve 4
A6-03
Setting for input of inflection
point 1 of AI curve 4
A6-04
Input of inflection point 2 of AI curve 4
A6-05
Setting for input of inflection
point 2 of AI curve 4
A6-06
Max. input of AI curve 4
A6-07
Setting for max. input of AI curve 4
A6-08
Min. input of AI curve 5
A6-09
Setting for min. input of AI curve 5
A6-10
Input of inflection point 1 of AI curve 5
A6-11
Setting for input of inflection
point 1 of AI curve 5
A6-12
Input of inflection point 2 of AI curve 5
Setting for input of inflection
A6-13
point 2 of AI curve 5
Max. input of AI curve 5
A6-14
A6-15
Setting for max. input of AI curve 5
AI1 sets jump point
A6-24
A6-25
AI1 sets jump range
A6-26
AI2 sets jump point
A6-27
AI2 sets jump range
A6-28
AI3 sets jump point
A6-29
AI3 sets jump range
0: not optimize
1: optimization model 1
2: optimization model 2
100%~200%
Name
AI curve setting of A6 group
-10.00V~A6-02
-100.0%~+100.0%
A6-00~A6-04
-100.0%~+100.0%
A6-02~A6-06
-100.0%~+100.0%
A6-06~+10.00V
-100.0%~+100.0%
-10.00V~A6-10
-100.0%~+100.0%
A6-08~A6-12
-100.0%~+100.0%
A6-10~A6-14
-100.0%~+100.0%
A6-12~+10.00V
-100.0%~+100.0%
-100.0%~100.0%
0.0%~100.0%
-100.0%~100.0%
0.0%~100.0%
-100.0%~100.0%
0.0%~100.0%
Setting range
- 64 -
Functional parameter table
1
150%
Default
Change
0.00V
0.0%
3.00V
30.0%
6.00V
60.0%
10.00V
100.0%
-10.00V
-100.0%
-3.00V
-30.0%
3.00V
30.0%
10.00V
100.0%
0.0%
0.5%
0.0%
0.5%
0.0%
0.5%

Publicité

loading