Specification of high-performance vector convertor
Torque control integral gain
P2-16
VF curve setting
P3-00
Torque boost
P3-01
P3-02
Cut-off frequency of torque boost
P3-03
Multi-point VF frequency point 1
P3-04
Multi-point VF voltage point 1
P3-05
Multi-point VF frequency point 2
P3-06
Multi-point VF voltage point 2
P3-07
Multi-point VF frequency point 3
P3-08
Multi-point VF voltage point 3
VF slip compensation gain
P3-09
VF over excitation gain
P3-10
VF oscillation suppression gain 0~100
P3-11
VF isolated voltage source
P3-13
VF isolated digital voltage
P3-14
setting
VF isolated voltage rise time
P3-15
0~60000
V/F control parameters in P3 group
0 : Straight line V/F
1 : Multipoint V/F
2 : Square V/F
3 : 1.2 power V/F
4 : 1.4 power V/F
6 : 1.6 power V/F
8 : 1.8 power V/F
9: Reserve
10 : VF complete separation mode
11 : VF semi-separation mode
0.0% : (Automatic torque boost)
0.1%~30.0%
0.00Hz~max. frequency
0.00Hz~P3-05
0.0%~100.0%
P3-03~P3-07
0.0%~100.0%
P3-05~rated frequency of motor (P1-04)
0.0%~100.0%
0.0%~200.0%
0~200
0 : Digital setting (P3-14)
1: AI1
2: AI2
3: AI3
4: PULSE setting (DI5)
5 : Multi-stage command
6 : Simple PLC
7: PID
8 : Communication given
Note: 100.0% correspond to the motor rated
voltage
0V~ rated voltage of motor
0.0s~1000.0s
Note: time for 0V changes to rated voltage
of motor
- 43 -
Functional parameter table
☆
1300
★
0
☆
machine type
★
50.00Hz
★
0.00Hz
★
0.0%
★
0.00Hz
★
0.0%
★
0.00Hz
★
0.0%
☆
0.0%
☆
64
☆
machine type
☆
0
☆
0V
☆
0.0s