Specification of high-performance vector convertor
Code
Effective mode selection 1 of DI
P4-38
terminal
Effective mode selection 2 of DI
P4-39
terminal
Output mode selection of FM
P5-00
terminal
FMR output function selection
P5-01
Relay function selection of
P5-02
control panel ( T/A-T/B-T/C)
Relay function selection of
P5-03
expansion card ( P/A-P/B-P/C)
DO1 output function selection
P5-04
Output selection of expansion
P5-05
card DO2
Name
0: valid high-level
1: valid low-level
Bit: DI1 Ten bit: DI2 Hundred bit: DI3
Thousand bit: DI4 Ten thousand bit: DI5
0: valid high-level
1: valid low-level
Bit:DI6 Ten bit: DI7 Hundred bit:DI8
Thousand bit: DI9 Ten thousand bit: DI10
Output terminal of P5 group
0 : Pulse output (FMP)
1 : Switching output (FMR)
0: No output
1: Operation of frequency convertor
2: Fault output (downtime)
3: Frequency level detection output FDT1
4: Frequency arrival
5: Zero speed operation (no output halt)
6: Pre-alarm of motor overload
7: Pre-alarm of convertor overload
8: Count value reaches the set
9: Reaching the set count
10: Length arrival
11: PLC cycle is complete
12: Set the accumulated run time
13: Frequency limit
14: Torque limit
15: Ready to run
16: AI1>AI2
17: Upper limit frequency arrival
18: Lower limit frequency reaches (running about)
19: Brown-state output
20: Communication Preferences
21: Positioning complete (reserve)
22: Location close (reserve)
23: Zero-speed operation 2 (shutdown also output)
24: Set the accumulated power-on time
25: Frequency level detection output FDT2
26: 1 to the output frequency
27: 2 to the output frequency
28: 1 to the output current
29: 2 to the output current
30: The timing to the output
31: AI1 input overrun
32: Carrying out
33: Reverse operation
34: Zero current state
35: Module temperature reached
36: Output current limit value
37: The lower limit frequency arrival (stop output)
38: Alarm output (continue)
39: Pre-alarm of motor overtemperature
40: The running time arrival
Setting range
- 46 -
Functional parameter table
Default
Change
00000
00000
0
0
2
0
1
4