Specification of high-performance vector convertor
When the drive each time you start, you start counting from 0, time remaining operating time by U0-20 view. Regular
operation time set by P8-43, P8-44, the time in minutes.
AI1 input voltage protection lower limit values
P8-45
AI1 input voltage protection upper limit values
P8-46
When the value is greater than the analog input AI1 P8-46, P8-47 less than or AI1 input, the output of the inverter
multifunction DO "AI1 input overrun" ON signal for indicating AI1 input voltage is within a set range.
Module temperature reached
P8-47
The inverter heat sink temperature reaches this temperature, the inverter output multifunction DO "module temperature
reaches the" ON signal.
P8-48
It is used to select the cooling fan operation mode selection 0. Inverter fan running in the running state, stop state if the heat
sink temperature is higher than 40 degrees then the fan is running, stop state radiator fan is not lower than 40 degrees
operation.
Select 1, the fan after power has been running.
P8-49
P8-50
P8-51
P8-52
This group used to implement the water supply system in sleep and wake function.
The inverter is running, when the set frequency is less than or equal P8-51 Sleep frequency, P8-52 after the delay time, the
drive goes to sleep, and automatically shut down. If the drive is in a dormant state, and the current run command, when the
set frequency greater than or equal frequency wake P8-49, P8-50 after a time delay, the drive started.
In general, set the wake-sleep frequency greater than or equal frequency. Sleep and wake-up frequency setting frequency
was 0.00Hz, then sleep and wake up function is invalid.
When hibernation is enabled, if the frequency source using PID, the PID sleep state whether operations by PA-28 affect the
function code, in which case you must select the shutdown operation when PID (PA-28 = 1).
Setting range
Setting range
Setting range
Cooling fan control
Setting range
Wake frequency
Setting range
Wake-up delay time
Setting range
Sleep frequency
Setting range
Sleep latency
Setting range
Factory default
0.00V~P8-46
Factory default
P8-45~10.00V
Factory default
0.00V~P8-46
Factory default
0: fan operates when running
1: The fan has been running
Factory default
Sleep frequency (P8-51) ~ maximum frequency (P0-10)
Factory default
0.0s~6500.0s
Factory default
0.00Hz ~ wake-frequency (P8-49)
Factory default
0.0s~6500.0s
- 116 -
Parameter description
3.10V
6.80V
75℃
0
0.00Hz
0.0s
0.00Hz
0.0s

Publicité