Specification of high-performance vector convertor
AI3 measured voltage 2
AC-10
Setting range
AI3 display voltage 2
AC-11
Setting range
The function code is used for analog input AI is corrected to eliminate the effect of AI input bias and
gain. The group function parameter had been corrected, restoring factory value, it returns to the factory
value after correction. Usually the application site does not require correction.
Found voltage means, such as a multimeter measuring instruments to measure out actual voltage,
voltage refers to the display inverter out of the sampled voltage value is displayed, see U0 group AI
before correction voltage (U0-21, U0-22, U0-23) display.
When the correction in each AI input port of each two input voltage values, respectively, the
multimeter to measure the value of the group read the value of U0 group, accurate input to the function
codes, the inverter will automatically AI zero bias and gain correction.
A01 target voltage 1
AC-12
Setting range
A01 measured voltage 1
AC-13
Setting range
A01 target voltage 2
AC-14
Setting range
A01 measured voltage 2
AC-15
Setting range
A02 target voltage 1
AC-16
Setting range
A02 measured voltage 1
AC-17
Setting range
A02 target voltage 2
AC-18
Setting range
A02 measured voltage 2
AC-19
Setting range
The function code is used for analog input AO is corrected to eliminate the effect of AI input bias
and gain. The group function parameter had been corrected, restoring factory value, it returns to the
factory value after correction. Usually the application site does not require correction.
Target voltage refers to the theoretical value of the inverter output voltage. Found voltage refers
measured by instruments such as multimeters actual output voltage value.
Factory default
-9.999V~10.000V
Factory default
-9.999V~10.000V
Factory default
0.500V~4.000V
Factory default
0.500V~4.000V
Factory default
6.000V~9.999V
Factory default
6.000V~9.999V
Factory default
0.500V~4.000V
Factory default
0.500V~4.000V
Factory default
6.000V~9.999V
Factory default
6.000V~9.999V
- 148 -
Parameter description
Calibration
Calibration
Calibration
Calibration
Calibration
Calibration
Calibration
Calibration
Calibration
Calibration