Parameter description
P8-12
Set the inverter reversing the transition process, the output of 0Hz at the time of transition, shown in Figure 6-15:
P8-13
Setting range
Set up the drive via the parameter is allowed to run in the inverted state, in the case of motor reversal is not allowed to set
P8-13 = 1.
Set frequency is lower than the lower limit frequency operation
P8-14
Setting range
When the set frequency is lower than minimum frequency, the operating status of the inverter can be selected using this
parameter. VFD offers three operating modes to meet various application requirements.
P8-15
This feature is typically used for load distribution of multiple motor drive with a load.
Droop control means that as the load increases, so that the inverter output frequency decreases, so more than one motor drive
the same load, the load of the motor output frequency drops more, thereby reducing the load of the motor to achieve multiple
motors load evenly.
This parameter refers to the inverter rated output load, the output value of the frequency drops.
Specification of high-performance vector convertor
Reversible dead time
Setting range
Figure 6-15 Reversible schematic dead time
Inversion of Control Enable
0
1
mode
0
1
2
Droop control
Setting range
Factory default
0.00s~3000.0s
Factory default
Factory default
Operation in lower limit frequency
Running at zero speed
Factory default
0.00Hz~10.00Hz
- 108 -
0.0s
0
Allow
Ban
0
Shutdown
0.00Hz