Parameter description
The function code unit, ten bit, hundred bit, corresponding to the analog input AI1, AI2, AI3. If this option is 0. When
the AI input below the "minimum input", corresponding to the analog setting function code to determine the curve
"minimum input corresponds to a given" (P4-14, P4-19, P4-24).
If this option is 1, then when AE input below the minimum input, the analog corresponding to 0.0%.
P4-35
Setting
P4-36
Setting
P4-37
Setting
When DI terminal for setting status changes, they are changes in the delay time of the inverter.
Currently only DI1, DI2, DI3 have set the time delay function.
DI terminal effective mode selection 1
P4-38
Setting
range
DI terminal effective mode selection 2
P4-39
Setting
range
It is used for setting the digital input terminal of the active mode. When choosing high effective, the corresponding S
terminal and COM communicated effectively, disconnect invalid. Selected as active low, the corresponding S terminal and
COM connectivity invalid, effectively disconnected.
P5 Group--Output terminals
This series inverter comes standard with a multifunction analog output terminal, a multi-function digital output
terminal, a multi-function relay output terminal, an FM terminal (selected as high-speed pulse output terminal, can also
choose a set open switch electrode output). As the output terminal can not meet the site with app, you need the optional
multi-function input and output expansion card.
Multi-function input and output expansion card output terminals, comprising a multi-function analog output terminal
(AO2), 1 multifunction relay output terminal (relay 2), a multi-function digital output terminal (DO2).
FM terminal output mode selection
P5-00
Specification of high-performance vector convertor
DI1 delay time
0.0s~3600.0s
DI2 delay time
0.0s~3600.0s
DI3 delay time
0.0s~3600.0s
Single digit
0
1
Ten bit
Hundred bit
Thousand bit
Ten thousand bit DI5 Terminal active set (0-1, supra)
Single digit
0
1
Ten bit
Hundred bit
Thousand bit
Ten thousand bit DI10 Terminal active set (0-1, supra)
0
Setting range
1
Factory default 0.0s
Factory default 0.0s
Factory default 0.0s
Factory default
DI1 terminal active set
Active High
Active Low
DI2 Terminal active set (0-1, supra)
DI3 Terminal active set (0-1, supra)
DI4 Terminal active set (0-1, supra)
Factory default
DI6 terminal active set
Active High
Active Low
DI7 Terminal active set (0-1, supra)
DI8 Terminal active set (0-1, supra)
DI9 Terminal active set (0-1, supra)
Pulse output (FMP)
Switching output (FMR)
- 94 -
00000
00000
Factory default
0