Specification of high-performance vector convertor
PC-13
PC-14
PC-15
Multi-step instructions can be used on three occasions: as the frequency source, as VF separate voltage source, as a process
PID setting source.
Under three applications, multi-stage instruction dimensionless relative value, range -100.0% to 100.0%. When the
frequency source as a percentage of its maximum relative frequency; VF as a separate voltage source, relative to the rated
motor voltage percentage; and because PID originally given as a relative value, multi-source does not command as PID set
dimension conversion.
Multi-step instruction required depending on the status of multi-function digital DI and switching options, please refer to the
P4 group specific instructions.
PC-16
Setting range
Simple PLC function has two roles: as the frequency source or as VF separate voltage source.
Figure 6-30 is a simplified schematic diagram of the PLC as the frequency source. When simple PLC as the frequency source,
PC-00 ~ PC-15 determines the direction of the positive and negative, negative if it means running the drive in the opposite
direction.
Running direction
DO or RELAY
output
As the frequency source, PLC operates in three ways, as a voltage source does not have VF separation of these three ways.
among them:
0: stop at the end of single running
Multi-stage instruction 13
Setting range
Multi-stage instruction 14
Setting range
Multi-stage instruction 15
Setting range
Simple PLC operation mode
0
1
2
PC-19
PC-21
PC-00
PC-18 PC-20 PC-23
Factory default
-100.0%~100.0%
Factory default
-100.0%~100.0%
Factory default
-100.0%~100.0%
Factory default
Stop at the end of single running
End of single running holding final value
PC-02
FC-01
Figure 6-30 Schematic
diagram of simple PLC
- 132 -
Parameter description
0.0%
0.0%
0.0%
0
Been circulating
PC-14
PC -15
time
250m spulse