Télécharger Imprimer la page

MSW Motor Technics MSW-FI-7500 Manuel D'utilisation page 282

Publicité

Specification of high-performance vector convertor
PE-25
PE-26
PE-27
PE-28
PE-29
This function code is customized parameter set.
Users can all VFD function code, select the desired parameter aggregated into PE group, as a user customized
parameters for easy viewing and changing operations.
PE group provides up to 30 custom parameter, PE group parameter display is P0.00, it means that the user function code is
empty. When entering custom parameters mode, display the function code PE-00 ~ PE-31 is defined by the order consistent
with the PE group function code, skip to P0-00
PP Group--User password
User Password
PP-00
Setting range
PP-00 to set an arbitrary non-zero number, the password protection function. The next time you enter the menu, you must
enter the correct password, or can not view and modify function parameters, please remember the password set by the user.
PP-00 is set to 00000, then clear the user password set, the password protection function is invalid.
PP-01
Setting range
1. Restore factory settings, excluding motor parameters
PP-01 is set to 1, most inverter function parameters are restored to the factory default parameters, but motor parameters,
frequency command decimal point (P0-22), fault recording information, total running time (P7-09), the cumulative power
time (P7-13), the total power consumption (P7-14) is not restored.
2. Clear History Information
Clear fault record information drive, total running time (P7-09), the cumulative power-up time (P7-13), the total power
consumption (P7-14).
4. The current parameter backup user
The current backup parameters set by the user. The current value of all settings function parameters back down. To facilitate
customers in the parameter adjustment disorder after recovery.
501, restore the user parameters previously backed up user parameters backup recovery, the recovery by setting PP-01 for the
four backup parameter.
User Function Code 25
Setting range
P0.00~PP.xx, A0.00~Ax.xx, U0.xx
User Function Code 26
Setting range
P0.00~PP.xx, A0.00~Ax.xx, U0.xx
User Function Code 27
Setting range
P0.00~PP.xx, A0.00~Ax.xx, U0.xx
User Function Code 28
Setting range
P0.00~PP.xx, A0.00~Ax.xx, U0.xx
User Function Code 29
Setting range
P0.00~PP.xx, A0.00~Ax.xx, U0.xx
Factory default
Parameter Initialization
0
1
2
4
501
Factory default P0.00
Factory default P0.00
Factory default P0.00
Factory default P0.00
Factory default P0.00
0~65535
Factory default
No operation
Restore factory settings, not including the motor
parameters
Clear History Information
Current backup user parameters
Recover user backup parameters
- 137 -
Parameter description
0
0

Publicité

loading